SENSOR
-
Infrared CO2 sensor measures the CO2 concentration automatically with high sensitivity.
-
For each shaker, a bottle of CO2 gas (20kg) can be used not less than 35days if the door is open normally, and about 145 days when door is not opened.
-
PT-100 temperature sensor
-
Humidity sensor (option)
DRIVE
-
Triple-eccentric drive is precisely counterbalanced to impart smooth, uniform motion to all flasks regardless of their position on the platform.
-
Servo-motor makes speed control precisely and ensures high-speed performance and stability.
SAFETY
-
Audible and Visible Alarms alert the user and shuts off heaters to setpoint deviation.
-
Automatic restart after power interrupt with Non-Volatile Memory keeps studies running smoothly.
-
The running will stop when the door is open. It is more safe.
CLEAN
-
Antibacterial stainless steelinterior chamber with rounded corners easy to clean and protect bacteria breeding.
-
Front door which is non-screw design and slide-out platform provide easy access to all samples.
-
With UV sterilization.
-
The bottom of the chamber can be washed thoroughly.
COOLING
-
High quality and low noise CFC free compressors ensure refrigeration effect and stable.
-
Special refrigerating process control technology with adjustable cooling capacity makes temperature control more accuracy.
-
Timing frost-removing function, the timing range is 1 to 89 minutes and the defrost interval is 30-600 minutes
adjustable, ensures machine working long time in low temperature without ice block.
Product Name |
|
|
Model |
ZCLY-180 |
ZCLY-100 |
Inner capacity |
221L |
168L |
Shaking Speed Range |
10-300 rpm |
|
Shaking Control Accuracy |
±1rpm |
|
Orbit (diameter) |
φ26mm |
|
Temp. Range |
Cooling 4℃~60℃(at 23℃~25 ℃) |
|
Temp. Accuracy |
±0.1℃ |
|
Temp. Uniformity |
±0.8℃(at 37℃) |
±0.5℃(at 37℃) |
Inner chamber material |
Antibacterial SUS304 stainless steel |
|
CO2 Control Range |
0-20% |
|
CO2 Control Accuracy |
0.1% |
|
Humidity Adjustment Accuracy |
1% optional |
|
Humidity Control Accuracy |
5% optional |
|
Humidity Control Range |
Ambient humidity~90% R.H optional |
|
Display |
LCD (4.3'' Touch Screen) |
|
Air circulation |
Forced air circulation |
|
Parameter Control |
P.I.D Microprocessor |
|
Timer Range |
0-999.9 hrs. |
|
Noise Level |
<55dB |
|
Power Source |
AC220±10% (110V is optional) 50~60Hz |
|
Each Platform Size (W×D,mm) |
485*485 |
485*410 |
Internal effective height |
563mm |
488mm |
Overall Dimension (W*D*H,mm) |
760*680*1280 |
600*766*998(1 unit) 600*766*1938(2-unit stacked) |
Net Weight(kg) |
183 |
125(1 unit) 255(2-unit stacked) |
Model |
ZCLY-180 |
ZCLY-100 |
||
Test tube rack |
4 |
3 |
||
Erlenmeyer Flask |
50ml |
Stainless steel |
81 |
56 |
100ml |
Stainless steel |
49 |
42 |
|
Plastic |
36 |
30 |
||
125ml |
Stainless steel |
36 |
42 |
|
150ml |
Stainless steel |
36 |
30 |
|
200ml |
Stainless steel |
25 |
30 |
|
250ml |
Plastic |
25 |
20 |
|
Stainless steel |
25 |
20 |
||
300ml |
Stainless steel |
25 |
20 |
|
500ml |
Plastic |
16 |
12 |
|
Stainless steel |
16 |
12 |
||
1000ml |
Plastic |
9 |
8 |
|
Stainless steel |
9 |
8 |
||
2000ml |
Plastic |
5 |
5 |
|
Stainless steel |
5 |
5 |
||
3000ml |
Plastic |
4 |
4 |
|
Stainless steel |
4 |
4 |
||
2800ml |
Stainless steel |
4 |
3 |
|
5000ml |
Stainless steel |
Double platforms are not enough to put 5L flask |
2 |
|
Dimensions of single platform(mm) |
485*485 |
485*410 |