Key Features:
- Unique horizontal double circulation air ducts
- Annular heating and refrigeration system.
- The automatic defrosting function is provided, and defrosting time, defrosting interval and automatic defrosting ON or not, etc. can be set.
- With humidification function of the bottom reservoir, with no water alarm function.
- Air duct UV sterilization function, sterilizing while culturing.
- External cloud platform interface is reserved, and the cloud platform system is optional.
Technical Specifications:
Model |
PUL-150 |
PUL-260 |
Supply voltage |
AC220V/50Hz |
AC220V/50Hz |
Power |
Max. 2000W |
Max. 2000W |
Display screen |
7-inch touch screen |
7-inch touch screen |
Volume of box |
175L |
300L |
Temperature control range |
0-70 ℃ (at RT25 ℃) |
0-70 ℃ (at RT25 ℃) |
Temperature display accuracy |
±0.1 |
±0.1 |
At r.t. 25 ℃ and set temperature of 37 ℃ |
the temperature uniformity is ≤± 0.3 ℃, and temperature fluctuation is ≤± 0.1 ℃ (9-probe temperature measurement) |
|
Temperature control mode |
PID microcomputer control |
PID microcomputer control |
CO2 range |
0-20% |
0-20% |
CO2 control accuracy |
±0.1%(5%,37℃) |
±0.1%(5%,37℃) |
CO2 resolution |
0.1% |
0.1% |
CO2 sensor |
Infrared CO2 sensor |
Infrared CO2 sensor |
CO2 control |
PID microcomputer control |
PID microcomputer control |
Inner material |
Antibacterial stainless steel |
Antibacterial stainless steel |
Sterilization function |
Equipped with UV sterilization function of air duct |
|
Number of plates |
Standard configured 3pcs |
Standard configured 4pcs |
Test hole |
Optional (inner diameter 38 mm) |
Optional (inner diameter 38 mm) |
Dimension of inner incubator |
≥W540×D560×H580mm |
≥W600×D560×H900mm |
External dimensions |
≤W770×D775×H1180mm |
≤W820×D780×H1500mm |
Cooling and heating methods |
The unique annular heating and cooling technology is adopted. |
|
Humidification method |
With humidification function of the bottom reservoir, with no water alarm function. |
|
Other Features |
The automatic defrosting function is provided, and defrosting time, defrosting interval and automatic defrosting ON or not, etc. can be set. |
|
External cloud platform interface is reserved, and the cloud platform system is optional. |
||
With data recording function, the recording time can be set, 150000 pieces of data can be recorded, and the temperature curves can be displayed to facilitate data analysis; there is a USB interface to export and save the above data. |
||
With overtemperature alarm function and overtemperature automatic heating switching-off function. |